Home Product Support Storage Disk Subsystems EMC² CLARiiON

EMC CLARiiON Disk Subsystems Support

 

  

EMC² Clariion Installation & Maintenance 

Free access web site for Installation & Maintenance procedures

 

 

Clariion AX

 

 Clariion CX

 

Clariion Software

CLARiiON-CX300_130.jpg

DAS Trainings

EMC Training


 

URGENT : data corruption and data lost risks on Clariion CX4 running R30-508 and earlier.

Regarding the ETA emc258303, the CX4 must be upgraded to the R30-509 (04.30.000.5.509).

In case of data corruption, the Clariion logs show "Coherency error detected" messages. In that case, you must apply the following action plan :

  1. Upgrade the CX4 to the R30-509
  2. Run a file check from the connected hosts to all Luns affected by the "Coherency error detected"
  3. Restore corrupted files

 

Assistance request
Create and track
Bull Search