PrKB15279 : NovaScale R620 & R620 E1 calendar correction patch
Some Fault-Tolerant servers R620 anf R620 E1 fail to maintain the system date every other year starting from 2010.
This issue is caused by a failure in the date calculation method of the hardware clock that may occur every even year.
Case 1 under Windows:
When the date goes from february 28th to feb. 29th, the date on the server will be march 1st.
Case 2 under Windows:
If a reboot occurs between feb 29th, 11:45 p.m. and march 1st, 4:00 am, the date on the server will be July 31, 2003.
Under Linux:
If a reboot takes place on February 28 or on February 29 between 11:45 p.m. and midnight, it will be July 31st 2003 on the server.
Please use the attached patches to correct this problem.
-----------------------------------------
Certains serveurs à tolérance de panne R620 et R620 E1 peuvent présenter un problème de date chaque année paire depuis 2010.
La cause vient d'un défaut dans le mode de calcul de l'horloge dans le chip.
Les occurrences du problème sont toutes les années paires depuis 2010.
Cas 1 en Windows :
Lorsque la date va passer du 28 au 29 Février, il sera le 1er mars sur le serveur
Cas 2 en Windows :
Si un reboot a lieu entre le 29 Février 23H45 et le 1er Mars 4H00, il sera le 31 Juillet 2003 sur le serveur.
En Linux :
Si un reboot a lieu le 28 ou le 29 Février entre 23h45 et minuit, il sera le 31 Juillet 2003 sur le serveur.
Les patches ci-dessous permettent de corriger ce problème.
FAQ Article