Click on a link below to go to a specific section of the software installation:
Install Requirements |
|
The Informix
iDataAgent in a Unix cluster can
be installed from the active node to the virtual server using the following
procedure. The software can also be automatically installed on all available
passive nodes when the software is installed onto the virtual server, or
you can choose to install any passive node(s) separately.
For an overview of deploying the software components in a clustered environment, see Clustering Support. The following procedure provides step-by-step instructions for installing the Informix iDataAgent on a Unix cluster. If you choose to install multiple components simultaneously, the sequence of the install steps may vary. Review the following Install Requirements before installing software on a Unix cluster: General
Firewall
Cluster
Agent SpecificComplete the following steps:
HP-UX
|
|
Install Checklist |
|
Collect the following information before
installing the software. Use the space provided to record the information,
and retain this information in your Disaster Recovery binder. The spaces for the client name and the various directories are intended to contain information regarding the virtual machine. Note that you may want to include multiple entries in these spaces if you are installing more than one virtual machine on the current host machine. |
|
General Information |
|
1. | Virtual client name:_____________________________ See Cluster Selection for more information. |
2. | Network interface name associated with the physical
machine:_____________________________ See Cluster Selection for more information. |
3. | Node name for the physical machine:_____________________________ See Cluster Selection for more information. |
4. |
Install directory location:________________________________________________________________
The default is /opt, but you may designate any location you want. See Base Software Installation for more information. |
5. |
Log files directory location:________________________________________________________________
The default is /var/log, but you may designate any location you want. See Base Software Installation for more information. |
6. |
Network TCP port number for the Communications Service (CVD):_____________________________ Network TCP port number for the Client Event Manager Service (EvMgrC):___________________________ See Base Software Installation for more information. |
7. |
If the CommServe Server and the client computer communicate across a firewall:
Firewall ports: ______________________________________________________________________ Hostnames and/or IP Addresses and corresponding GxCVD port numbers of computers on the other side of the firewall:______________ Keep Alive Interval minutes:____________________________________________________________ Hostname for outgoing tunnel connections:_________________________________________________ Tunnel Initialization Interval seconds:_____________________________________________________ See Firewall Configuration for more information. |
8. |
CommServe Name and the CommServe Host Name:______________________________________
For example, orange and orange.domainname.com. See Base Software Installation (continued) for more information. |
9. |
Job result directory location:________________________________________________________________
The default is /opt, but you may designate any location you want. See Base Software Installation (continued) for more information. |
10. |
Storage Policy used by the default subclient:________________________________________________
See Storage Policy Selection for more information. |
11. |
Client Group to which this Client will be associated:_____________________________________________
See Client Group Selection for more information. |
Informix Specific Information |
|
12. |
Informix User ID:______________________________________________________________________
Informix User Group:___________________________________________________________________ ONCONFIG File Name:_________________________________________________________________ Informix Instance Name:________________________________________________________________ Informix Libraries Path:_________________________________________________________________ See Configure Informix Specific Information for more information. |
Before You Begin |
|
|
Install Procedure |
||
Getting Started |
||
1. |
Place the software
installation disc for the Unix platform into the disc drive. You can also install the product using a disc drive mounted on another computer on the network.
|
|
2. |
The product banner and other information is displayed.
Press Enter to continue. |
|
3. | Read the license agreement. Type y and press Enter to continue. | |
Cluster Selection |
||
4. | Type 2 and press Enter to install on a virtual machine. |
Certain Calypso packages can be associated
with a virtual IP, or in other words, installed on a "virtual machine" belonging
to some cluster. At any given time the virtual machine's services and IP address
are active on only one of the cluster's servers. The virtual machine can
"fail-over" from one server to another, which includes stopping services and
deactivating IP address on the first server and activating the IP
address/services on the other server.
You now have a choice of performing a regular Calypso install on the physical host or installing Calypso on a virtual machine for operation within a cluster. Most users should select "Install on a physical machine" here. 1) Install on a physical machine 2) Install on a virtual machine 3) Exit Your choice: [1] |
5. | Type the name of the virtual machine that you want to configure or its corresponding IP address and press Enter. | Please enter the hostname
or IP address of the virtual machine being installed. It can be either short
or long; the only requirement is that it must be resolvable by the name
services configured on this machine WARNING: You should follow this path ONLY if this host participates in a cluster and you really want to install Calypso on the virtual machine. This is NOT how most people will use Calypso. If you got into this screen by mistake, hit ^C and restart cvpkgadd. Virtual Machine Host Name: |
6. | This prompt appears if you entered the short form of the virtual machine host name in the previous step. If you want to use the long form of the host name, accept the yes default; if not, type no. Then press Enter. | It looks like name "example.company.com"
resolves to the same IP as "example". Generally, it's better to use longer
name to address a host: less chances for name-to-IP resolution problems
on CommServe or other IDA/MA.
Would you like to use fully qualified "example.company.com" instead of "example"? Use longer "example.company.com" name? [yes] |
7. | If you have already installed the software on the virtual
machine for the active node, accept the yes default to install for
the passive node, press Enter, and go to the next step.
If you still must install for the active node, type no, press Enter, and perform the install for the virtual machine for the active node. NOTES
|
When installing new
Calypso
packages on a virtual machine, you should start with the active node, that
is the host where the virtual machine is currently running. This node appears to be passive, so we will assume that you have already installed Calypso for example.company.com on the active node. Is this correct? [yes] |
8. | Type the name of the virtual client and press Enter. | Please specify the client
name for this machine.
It does not have to be the network host name: you can enter any word here without spaces. The only requirement is that it must be unique on the CommServe. Virtual Machine Client Name: [hpuxmc1] |
9. | Specify the network interface that you want to associate
with the physical machine and press Enter. NOTES
|
Even though it is a virtual
machine that you are installing now, we still have to ask you to provide
hostname and client name for the physical node.
Network interfaces with the following IPs are available on your system. Please select the one that you want to be associated with Calypso physical machine. The interface should be static, and should not get disabled in case of cluster failover. 1) mackrel71 Interface number: [1] 2 |
10. | Verify the name of the physical interface and make any required changes. Then press Enter. | Please verify the physical
interface name below. Make it as complete (with fully qualified domain name)
as possible.
Physical Hostname: [mackrel] |
11. | Enter a node name for the physical machine and press Enter. | Even though you are installing
Calypso on a machine, we still need to ask you to provide a node name for
the physical machine.
It does not have to be the network host name: you can enter any word here without spaces. The only requirement is that it must be unique on the CommServe. Physical Machine Node Name: [mackrel] |
Select Components for Installation |
||
12. | Enter the number corresponding to the CVGxIfIDA
module.
NOTES
Press Enter to continue. |
Install Calypso on
physical machine client.company.com Select the Calypso module that you would like to install
1) Media Agent <=
CVGxMA Module number: [1] |
Base Software Installation |
||
13. | Select from the following:
|
Here is a list and status of the dependent
modules:
1) Calypso Base0 Module NOT installed 2) Calypso Base Module NOT installed If there are any modules listed as NOT installed/upgraded, they will be installed/upgraded first. Press <ENTER> to proceed ... |
14. |
Specify the location where you want to install the software.
NOTES
Press Enter to accept the default path and continue, or Press Enter again to confirm the path. |
Please specify where you want us to install
Calypso binaries.
It must be a local directory and there should be at least 170MB of free space available. All files will be installed in a "calypso" subdirectory, so if you enter "/opt", the files will actually be placed into "/opt/calypso". Installation Directory: [/opt] .. Calypso will be installed in /opt/calypso.
|
15. |
Specify the location for the log files.
NOTES
Press Enter to accept the default path and continue, or Press Enter again to confirm the path. |
Please specify where you want to keep
Calypso log files.
It must be a local directory and there should be at least 100MB of free space available. All log files will be created in a "calypso/Log_Files" subdirectory, so if you enter "/var/log", the logs will actually be placed into "/var/log/calypso/Log_Files". Log Directory: [/var/log] .. Calypso log files will be created in /var/log/calypso/Log_Files. |
16. |
Indicate whether you would like to launch processes with inherent database
access rights.
Press Enter to
assign a new group, or |
Most of Calypso processes run with root
privileges, but some are launched by databases and inherit database access
rights. To make sure that registry and log files can be written to by both kinds
of processes we can either make such files world-writeable or we can grant write
access only to processes belonging to a particular group, e.g. a "calypso" or a "dba"
group.
We highly recommend now that you create a new user group and enter its name in the next setup screen. If you choose not to assign a dedicated group to Calypso processes, all temporary and configuration files will be created with -rw-rw-rw permissions. If you're planning to backup Oracle DB you should use "dba" group. Would you like to assign a specific group to Calypso? [yes] |
17. |
If you indicated Yes in the previous step, you will be prompted for
the group name that must be used to launch processes.
Enter the group name and then press Enter to continue. Press Enter again to continue. For installs on a Solaris computer, proceed to the next step. Otherwise, skip to Storage Policy Selection. |
Please enter the name of the group which
will be assigned to all Calypso files and on behalf of which all Calypso processes
will run.
In most of the cases it's a good idea to create a dedicated "calypso" group. However, if you're planning to use Oracle iDataAgent or SAP Agent, you should enter Oracle's "dba" group here. Group name: dba REMINDER If you are planning to install Calypso
Informix, DB2, Sybase or Lotus Notes iDataAgent, please make sure to include
Informix, DB2, etc. users into group "dba". |
18. |
Type a network TCP port number for the Communications Service (CVD) and press Enter.
Type a network TCP port number for the Client Event Manager Service (EvMgrC) and press Enter. NOTES
|
Every instance of Calypso should use a unique set of network ports to avoid
interfering with other instances running on the same machine. The port numbers selected must be from the reserved port number range and have not been registered by another application on this machine. Please enter the port numbers. Port Number for CVD : [8400] Port Number for EvMgrC: [8402] |
Firewall Configuration |
||
19. |
If this computer communicates with the CommServe, MediaAgent and/or other
clients across a
firewall, type Yes, and then press Enter to continue. Proceed to
the next Step. Press Enter, if you do not wish to configure the firewall services. Proceed to the next section. |
Various Calypso components need to
communicate with each other: iDataAgents and MediaAgents establish connections
to CommServe and talk to each other as well. If any of the involved parties are
situated on the opposite sides of a firewall, Calypso should be made aware of it
so that it could bind its pipeline sockets to open ports and could establish
tunnels for control traffic. You must configure Calypso firewall services if there are other Calypso machines, which are expected to communicate with this one. Do you want to configure Calypso firewall services? [no] |
20. |
Enter the port range(s), and then press Enter to continue.
NOTES
|
Calypso needs to know which TCP ports of this machine are available for
connections initiated by machines on the other side of the firewall.
If this machine is not reachable from the other side of the firewall at all
(because the FW is one-way and allows only outgoing connections), enter any
unused port number here (e.g. 8600). Currently there are no ports configured. Please enter a single port number or a port range (like 8600-8620) to be added to the FW configuration: Port range: [8600-8620] |
21. |
Enter the number corresponding to the option you wish to perform. NOTES
|
What would you like to do: 1) Add another open port or a range of ports 2) Delete an existing port or a range of ports3) Continue with the firewalled host setup Your choice: [3] |
22. | Enter the host name(s) of the computers that will need to be contacted through a firewall, and then press Enter to continue. |
We need to know which Calypso hosts are located on the other side of the
firewall, and whether the firewall will allow direct or reverse connections
to/from those hosts.
You can specify hosts by either entering their names, IP addresses or name/IP wildcards. The wildcards are available only if the firewall is symmetrical, i.e. allows to open connections to certain ports both ways. Currently there are no firewall hosts configured. Please enter the name or IP address of a host on the other side of the firewall. If the firewall is symmetrical, you are allowed to use wildcards, i.e. things like 192.168.* or *.firewall.company.com: Firewalled Host: lavender.company.com |
23. |
Choose the option associated with type of firewall configuration based on the
firewall setup in your environment.
NOTES
|
Please specify the type of the firewall separating this machine from
172.19.61.89.
1) Two-way (symmetrical) firewall 2) One-way firewall, 172.19.61.89 is reachable from here 3) One-way firewall, this machine is reachable from 172.19.61.89 Your choice: [1] |
24. |
Enter the number corresponding to the option you wish to perform. NOTES
|
What would you like to do: 1) Configure another host 2) Delete an existing host 3) Continue with the firewall keep-alive setup Your choice: [3] 1 |
25. |
If desired, modify the Keep Alive interval, and then press Enter to
continue, or Press Enter to accept the default. |
Please specify Keep Alive interval for Calypso firewall services.
Many firewalls disconnect idle Network connections after some period of time.
Some of the Calypso Services need continuous connections. Calypso keeps such
connections active by sending periodic "keep-alive" packets. Keep-alive interval, minutes [5] |
26. |
To configure advanced
firewall settings, type Yes, and then press Enter. Proceed to
the next Step. If you do not want to configure advanced firewall settings, type No, and then press Enter. Proceed to the next section. |
The Generic part of the Calypso Firewall Config has been completed
successfully. There are some additional advanced settings that you may want to
review now. All of them can be customized later by editing the .properties file
under /etc/CommVaultRegistry/Galaxy/Instance003/Firewall. Would you like to review the advanced settings now? [no] |
27. |
To bind the local end of tunnel connections to a specified interface, type Yes, and then press Enter. Proceed to
the next Step. If you do not want to bind the local end of tunnel connections to a specified interface, type No, and then press Enter. Skip the next Step. |
Normally Calypso Firewall code doesn't bind
local end of TCP/IP sockets when establishing outgoing tunnel connections
relying on the OS to pick correct interface and arbitrary port automatically.
Usually this doesn't cause connectivity problems because we require that the
firewall must allow connections for as long as 1meither source or destination
socket end is bound to one of the ports in the open range.
Sometimes, however, on hosts with several NICs it's important to force the OS to bind the local socket end to a specific network interface. There is a Calypso setting called 1mnBIND_BEFORE_CONNECT_IFACEm, which enables this behavior. If present, Calypso will bind the local end of tunnel connections to the specified interface. Would you like to configure nBIND_BEFORE_CONNECT_IFACE? [no] |
28. |
Type a number corresponding to one of the listed network interfaces, to use for outgoing tunnel connections through
the firewall. Press Enter to continue. |
Please select network interface that should
be used for all outgoing tunnel connections:
1) <ip_address> Interface number: [1] |
29. |
If desired, modify the Tunnel Initialization interval by typing a number. Press Enter to continue. |
When tunnel to a destination machine cannot be
established because the machine is down or is not accepting connections, Calypso
will retry the connection after some time. Tunnels piercing one-way firewalls are
1mPERSISTENTm meaning that Calypso will keep on trying to initialize them until
success. These attempts can generate a lot of network traffic if a central machine
(e.g. CommServe) suddenly goes down.
Here you can adjust the interval (called 1mnTUNNEL_INIT_INTERVALm in registry) between tunnel init attempts. Tunnel Init Interval, seconds, [5] |
Base Software Installation (continued) |
||
30. |
Type the name of the CommServe computer and press Enter to continue.
NOTES
|
Please enter the hostname of the Calypso
CommServe. It can be either short or long; the only requirement is that it must
be resolvable by the name services configured on this machine.
CommServe Name: |
31. |
Enter the username and password information for an external
domain user account or a CommCell user account. This authorizes the installation
of an agent on the CommCell.
NOTES
Click Enter to continue. |
Enter your CommCell user name and password: User Name : Password : Press <ENTER> to continue ... |
32. |
Specify the location of the job results directory. NOTES
Press Enter to accept the default path and continue, or |
Please specify the name
for the JobResults directory.
Since you are installing Calypso on a virtual machine, the JobResults directory must reside on a shared disk and should have at least 20MB of free space available. The directory will be used to store intermediate data that should be passed from one backup phase to another. JobResults Directory: [/swtitchover/] |
Kernel Parameters |
||
33. |
Enter the appropriate number of streams, and then press Enter to
continue, or Press Enter to accept the default number of streams and continue. NOTES
This prompt is relevant only when you install/upgrade on a Macintosh or Solaris computer as appropriate. |
Please enter the total number of streams that you plan to run at
the same time. We need to make sure that you have enough semaphores and shared
memory segments configured in /etc/system.
Number of streams: [10] |
34. |
Indicate whether you would like modifications to be made to the
/etc/system configuration file.
Type Yes, and then press Enter to
automatically update the file and continue, or This prompt is displayed only when you install/upgrade on a Solaris or Macintosh computer. |
We now need to modify the /etc/system configuration file on this
computer. It is done to make sure that there will be enough shared memory and
semaphores available for Calypso programs.
Please review the changes below and answer "yes" if you want us to apply them to the /etc/system file. Otherwise, the installation will proceed, the changes will be saved to some other file, and you will have to apply them manually. set shmsys:shminfo_shmmni=8570 (was 7930) Do you want us to apply these changes now? [no] Changes saved into /etc/system.gal.1744 Press <ENTER> to continue. |
35. |
If you indicated No in the previous step, the file to which the
changes have been saved is displayed. Make sure that these values are established later to ensure that all the requirements for this setup is satisfied. NOTES
Press Enter to continue. This prompt is displayed only when you install/upgrade on a Solaris computer, in cases where the install detects that the computer does not have the maximum or minimum required shared memory settings. |
Although a ’no’ answer can be selected to this question during
install, the user should make sure the min requirements (below) for shared
memory are met, otherwise the backups may fail (the message in logs is ’could
not start the pipeline’).
set shmsys:shminfo_shmmax=4199304 |
Storage Policy Selection |
||
36. |
Enter the number corresponding to the storage policy through which you want to back up
the File System iDataAgent and then press Enter to continue.
NOTES
|
Please select one storage policy for this IDA from the list
below:
1) SP_StandAloneLibrary2_2 Storage Policy: [3] |
Enable Global Filters |
||
37. |
Type the appropriate number for configuring Global Filters for the default
subclient and press Enter to continue.
NOTES
|
Commcell Level Global Filters are set
through Calypso GUI's Control Panel in order to filter out
certain directories or files from backup Commcell-widely. If you turn on the
Global filters, they will be effective to the default subclient. There are three
options you can choose to set the filters.
1) Use Cell level policy Please select how to set the Global Filters for the default subclient? [1] |
Client Group Selection |
||
38. |
Type the number of a Client Group and press Enter.
A confirmation screen will mark your choice with an "X". Type the number for Done with the Selection, and press Enter to continue. NOTES
|
Client Group(s) is currently configured on CommServe
cs.company.com.
Please choose the group(s) that you want to add this client
client.company.com to. The selected group(s) will be marked (X) and can be
deselected if you enter the same number again. After you are finished with the
selection, select "Done with the Selection". 1) Unix 2) DR 3) DKS 4) Done with the selection Please enter a number to select/deselect: [1] |
Configure Informix Specific Information |
||
39. | You are advised that the system is preparing to relink Informix. Press Enter. |
The control now passes to the Ifx_install.sh script to allow
it to relink Informix.
Press ENTER to continue. Installing Bull Calypso Onbar..... |
40. |
You are asked if you want to relink the Informix instance now. This is required
before performing backups.
Skip the next step. |
Do you wish to relink Informix instance now? (n/[y]) |
41. |
The Informix instance is relinked. Once this is done, this message
displays. Press Enter.
Skip the next step. |
We are back from Ifx_install.sh Press <ENTER> to continue. |
42. | You are warned that Informix must be relinked before performing backups and are provided with the appropriate post-install instructions. Press Enter. | WARNING: relink of Informix is required before performing backups. Please execute /opt/calypso/iDataAgent/Ifx_ionstall.sh to relink Informix after the install |
43. |
You are prompted to specify the Informix User ID. This is the user ID that is used
by the system to log in to the Informix database. Enter the Informix User ID or accept the default value and press Enter. |
Please enter INFORMIX_USER ID [informix]: |
44. |
You are prompted to specify the user group for Informix. Enter the user group name or accept the default value and press Enter. |
Please enter user group for informix [informix]: |
45. |
You are prompted to enter the Informix home directory.
Enter a path and press Enter. |
Please enter INFORMIXDIR directory: |
46. |
You are prompted to enter the name of the appropriate ONCONFIG file. This file
helps to administer the number of streams, among other capabilities. Enter the file name and press Enter. |
Please enter the ONCONFIG environment variable: |
47. |
You are prompted to enter the name of the Informix instance.
Enter the name of the instance and press Enter. |
Please enter the INFORMIXSERVER environment variable: |
48. |
You are prompted to enter the path to the Informix libraries. Enter the path or select the default and press Enter. |
Please enter the BAR_BSALIB_DIR [/usr/lib]: |
49. |
If the Informix Dynamic Server version is the same or earlier than the identified
version:
If the Informix Dynamic Server version is later than the identified version:
Skip the next step. |
Is your Informix Dynamic Server version is 7.30/9.14 or earlier? ([y]/n): |
50. |
For Informix 7.30/9.14 or earlier, the bar_version table is updated, and information similar to the
example shown to the right is displayed. When prompted, press Enter to continue.
Skip the next step. |
The database inf_730 must be On Line before installing, if
not, please startup the database inf_730 in another window or
exit and try /opt/calypso/iDataAgent/Ifx_install.sh
script again after the installation is complete! Do you wish to continue? (y/[n]) y CXDIR:/opt/calypso/Base64, IFXLIBPATH:/usr/lib/sparcv9 Updating Onbar Version Database INFORMIXDIR=/backup_area/informix INFORMIXSERVER=inf_730 ONCONFIG=onconfig.inf_730 Check if the bar_version table existed in the database Database selected. bar_version bsa_version bar_sm sm_version 1 1.1.1 cvsm 1 1 1.1.1 cvsm 1 1 1.1.1 cvsm 1 1 1.1.1 cvsm 1 1 1.1.1 cvsm 1 1 1.1.1 cvsm 1 1 1.1.1 cvsm 1 1 1.1.1 cvsm 1 1 1.1.1 cvsm 1 1 1.1.1 cvsm 1 10 row(s) retrieved. Database closed. Updating bar_version table Database selected. 1 row(s) selected. Database closed. Installation completed. We are back from Ifx_install.sh Press <ENTER> to continue... |
51. | For any Informix version higher than 7.30/9.14, you are eventually notified that there is no bar_version table, that the system will update the sm_version table instead, and that you should ignore the displayed error message. (As requested after the first message that appears, type y and press Enter to continue.) |
The database inf_921 must be On Line before installing, if
not, please startup the database inf_921 in another window or
exit and try /opt/calypso/iDataAgent/Ifx_install.sh
script again after the installation is complete! Do you wish to continue? (y/[n]) y CXDIR:/opt/calypso/Base64, IFXLIBPATH:/usr/lib/sparcv9 Updating Onbar Version Database INFORMIXDIR=/tigger/informix/informix921 INFORMIXSERVER=inf_921 ONCONFIG=onconfig.inf_921 Check if the bar_version table existed in the database Database selected. 206: The specified table (bar_version) is not in the database. 111: ISAM error: no record found. Error in line 2 Near character position 26 Database closed. ------------------------------------------------------ For the Informix Server version 7.30 or earlier than 7.30, Calypso will update bar_version table; For the Informix Server version later than 7.30, there is no bar_version table, Calypso will update sm_versions instead, ignore above error ------------------------------------------------------- Installation complete. |
52. |
The following message is displayed. As prompted, include the indicated
parameter into the ONCONFIG file, then press Enter to continue.
NOTES
|
Put "BAR_BSALIB_PATH /usr/lib/sparcv9/ibsad001.<xx>" into configuration file onconfig.inf_921. Replace <xx> with the shared library file extension, e.g., ibsad001.so is for SOLARIS, ibsad001.sl is for HP. We are back from Ifx_install.sh Press <ENTER> to continue... |
53. |
If you do not want to relink another Informix instance now:
If you want to relink another Informix now:
|
Do you wish to relink another informix instance now? (y/[n]) |
54. | You are advised that the installation is completed, and you are provided with instructions for installing other Informix instances. Press Enter. |
Installation complete. If you wish to install other Informix
instances, please execute /opt/calypso/iDataAgent/Ifx_install.sh after
installation We are back from Ifx_install.sh Press <ENTER> to continue... |
55. | If you have multiple instances of the database, ensure that the items listed are satisfied. Press Enter. |
IMPORTANT If you are planning to use Calypso <package> with several instances of the database, each running on behalf of different UNIX users, you must make sure that: 1) All database users have been added to each of the database groups involved. For example, if there is a "db2inst1" user from group "dba1" and "db2inst2" user from group "dba2", then both "db2inst1" and "db2inst2" should be included into "dba1" and "dba2" groups. On most UNIXes this can be accomplished by editing the /etc/group file. 2) The .profile of each database user must contains a "umask 002" command at the end, which will guarantee that all files created by one database user can be open for writing by other database users. 3) All database users should be added to the "dba" group that you have chosen for Calypso at the time of CVGxBase install. If all of the above requirements are not fulfilled, Calypso will run into various "Permission denied" errors, and backups will not work. Press <ENTER> to continue ... |
56. | Press Enter to continue. |
Updating registry tree under /etc/Registry ... done. Preconfiguring Informix DataAgent on the CommServe ... done. Successfully installed CVGxIfIDA. Press ENTER to continue ... |
Setup Complete |
||
57. |
Press Enter to continue.
NOTES
|
+---------------------+
IMPORTANT: In addition to installing Calypso on this computer, you will also need to create a Job Schedule for each iDataAgent that has been installed on this client computer. Job Schedules are required to allow the Calypso iDataAgents to perform automated backup and restore operations. Job Schedule creation can be accomplished through the Calypso CommCell Console administration interface. +---------------------+ Successfully installed CVGxIDA. |
58. | This menu may be displayed only when you are installing
on HP-UX, Linux, or Solaris computers.
If this is the last package that you wish to install/upgrade, enter the number
corresponding to the Return option and then press Enter to
continue.
NOTES
|
Select the Calypso module that
you would like to install. 1) Proxy FileSystem iDataAgent <= CVGxProxyIDA Module number: [1] |
59. |
Enter Yes to download and install the latest service packs and post packs from the software provider. NOTES
Press Enter to continue. |
Download and Install Latest Service Pack If you choose to download the latest service pack from the software provider website now, please make sure you have internet connectivity at this time. This process may take some time depending on the internet connectivity. Do you want to download the latest service pack now ? [no] Press <ENTER> to continue ... |
60. | This prompt is displayed only when you are installing on
HP-UX, Linux, or Solaris computers.
Enter the number
corresponding to the Exit option and then press Enter to
continue.
The installation is now complete. |
Calypso is currently configured
on virtual machine hpuxmc1.company.com. Now you have an option of installing Calypso on physical machine, another virtual machine or you can add a new package to hpuxmc1.company.com. 1) Add a new package to hpuxmc1.company.com Your choice: [1] |
Post-Install Considerations |
||
General
The software provides many more features that you will find useful. See the Index for a complete list of supported features. Cluster
Informix
Disaster Recovery Considerations
|